To overcome these challenges, HYDAC offers:
- Varnish Elimination Unit – Filtration (VEU-F) to remove varnish;
- Stat-Free elements to protect against electrostatic charging; and
- Stat-X filter elements to fully eliminate electrostatic charging in very low conductivity oils.
HYDAC Fluid Power Engineer Albert Dobis highlights that removing varnish after it has formed only removes the symptoms and not the root cause.
Gas turbine operation poses challenges to companies
Varnish comes from the breakdown or degradation of oil in the system, Mr Dobis comments.
“The most common modes of turbine oil degradation are oxidation, thermal degradation, and foreign contaminant degradation,” he says.